On a gas furnace the sequence is the call for heat from the thermostat, the inducer starting, the hot-surface ignitor warming, the gas valve opening, the flame sensor proving the flame, and the blower coming on. Failures sit in a predictable order: an ignitor that has aged out, a flame sensor fouled with residue, a pressure switch that will not prove, or a limit switch opened because airflow across the heat exchanger is too low.
A heat pump runs a different set. The reversing valve shifts the unit between heating and cooling, and the defrost board periodically cycles the system to clear frost from the outdoor coil. A short hiss and a brief pause during cold weather is normal defrost behavior, not a fault. When the auxiliary strips carry the house too often, the conversation is about setpoint, staging and how the system was set up.
Heat exchanger condition is checked whenever a furnace presents with cracked-appearing surfaces, soot, or repeated limit operation. A compromised heat exchanger is a safety issue, and the equipment is shut down until it is evaluated.